beautypg.com

Yaskawa i80M Maintenance Manual User Manual

Page 113

background image

4.3.2.2

DETAILS OF FUNCTION

M e m o r y C h e c k

Backup memory CMOS existing only in model JAN CD-

board and ROM/RAM memory on all CPU

boards are self-diagnosed.

Self-diagnosis includes items checked at system
startup and after startup.

( a )

( i )

CMOS Check

T o t a l C h e c k

Total check is made after system startup and CMOS
error is detected by total check sum on CMOS
memory.

This check is performed or not depending on the
system number.

a

A

I

Numbers checked . . .

I

When an error occurs in CMOS, the following alarms
are generated:

I

ALM109O: Setting total check error
ALM1091: Parameter total check error
ALM1092: Keep memory total check error

ALM1093: Offset total check error
ALM1094: Macro program variable total check

error

ALM1095: Processing program total check error

If an alarm occurs for some reason, CMOS data may

be destroyed.

The alarm can be erased by tempo-

rarily writing the data from the CRT control panel,

then depressing the

ESE

key on the control panel.

No alarm can be erased for processing programs.

105