10   Device Settings

SMA Solar Technology AG

62

SPortal-WB-CLCON-BA-en-25

User Manual

Explanation of device properties – Device status of the Cluster Controller

• To display the device status of the Cluster Controller, select the "Device Characteristics" page

of the Cluster Controller and go to the "Device status" tab.

Designation

Meaning

Device status

Indicates the device status of the Cluster Controller
(see page 43).

Grid management

Indicates whether grid management is activated in the
Cluster Controller (see the Cluster Controller user
manual).

Active power limitation*

*The data for active power limitation and cos Phi setpoint are displayed when the respective function is activated.

Parameter for active power limitation

Cos Phi setpoint*

Parameter for the cos Phi setpoint

Target value

Indicates the current target value for active power
limitation or the cos Phi setpoint. The target value is
specified by the network operator.

Actual set value

Indicates the current actual set value for active power
limitation or the Cos phi setpoint. The actual set value is
sent to the inverters by the Cluster Controller.

Source of target value

Indicates the type of signal source.

Last contact

Shows the date and time of the last contact between the
Cluster Controller and the Sunny Portal.