2 1 vpp measuring system with endat interface – HEIDENHAIN PWM 8 User Manual
Page 77
- 77 -
18.8 Pin layouts of drive encoders and absolute encoders
18.8.1 1 Vpp measuring system with Zn/Z1 track
17-pin HEIDENHAIN flange socket
Interface board flange socket:
IN
Interface board flange socket:
OUT
15
16
12
13
3
2
7
10
1
4
6b
2a
3b
5a
4b
4a
1b
5b
7a
3a
A B R
+
– + – + –
5 V
UP
0 V
UN
5 V
Sensor
0 V
Sensor
Green /
Black
Yellow /
Black
Blue /
Black
Red /
Black
Red
Black
Brown /
Green
White /
Green
Blue
White
11
14
17
9
8
5
6
-
7b
1a
2b
6a
-
-
C D
Temperature
Internal
shield
+
– + – + –
-
Gray
Pink
Yellow
Violet
Green
Brown
18.8.2 1 Vpp measuring system with EnDat interface
17-pin HEIDENHAIN flange socket
Interface board flange socket:
IN
Interface board flange socket:
OUT
15
16
12
13
14
17
8
9
7
10
2a
5b
4a
3b
6b
1a
2b
5a
1b
4b
A B
+
– + –
+DATA
-DATA
+CLOCK
-CLOCK
5 V
UP
0 V
UN
Green /
Black
Yellow /
Black
Blue /
Black
Red /
Black
Gray
Pink
Violet
Yellow
Brown /
Green
White /
Green
11
1
4
3
2
5
6
-
6a
3a
-
-
-
-
Internal
shield
5 V
Sensor
5 V
Sensor
n.c.
n.c.
n.c.
n.c.
-
Blue
White
Red
Black
Green
Brown
Serial EnDat output signals
Being a bi-directional interface, the EnDat interface (Encoder Data) of the absolute encoders can output
absolute position values as well as request or update information stored in the encoder. Owing to serial
data transfer, 4 signal lines are sufficient. The data transfer mode (position values or parameters) is
selected via MODE commands which the encoder receives from the subsequent electronics. The data
transfer is synchronized with the CLOCK signal given by the subsequent electronics.
PCB connector
on encoder
:
PCB connector
on encoder
: