beautypg.com

7 specifications of htl interface board, 8 specifications of power supply unit – HEIDENHAIN PWM 8 User Manual

Page 42

background image

-

42

-

8.7 Specifications of HTL Interface Board


Maximum input voltage:

0 - 30 V

Maximum input frequency:

approx. 2 MHz


Note:
The maximum input frequency only stands for the cutoff frequency of the square-wave input at PWM 8
(signal source: frequency generator).

Measure U/I:
Measuring range

current:

0 - 500 mA

Measuring range

voltage:

0 - 30 V

Tolerance:

±

5 %


Measure amplitudes:
Measuring range

high level:

17.5 - 22.5 V

Measuring range

low level:

0 - 7.5 V

Resolution:

100

mV

Measuring frequency:

10 Hz - 200 kHz

Tolerance:

±

100 mV


Terminating resistance:
From encoder signal to U-MSYS

1200

From encoder signal to GND

1200


Special feature of HTL interface board:
If the inverted are missing at the encoder output, they are generated internally and output
at the encoder output.

8.8 Specifications of Power Supply Unit


Input voltage:

100 - 240 V ac, 50 - 60 Hz

Output voltage:

24 V dc, 1.0 A

Protection

grade:

1

Maximum ambient temperature:

40 °C