4 specifications of 11µapp interface board, 5 specifications of 1vpp interface board – HEIDENHAIN PWM 8 User Manual
Page 40

-
40
-
8.4 Specifications of 11µApp Interface Board
Signal amplification (Ie1, Ie2, Ie0):
300
mV
A
m
Input amplifier:
Maximum signal current:
Ie0, Ie1, Ie2: 66 µApp
Maximum frequency at encoder input:
-3
dB:
approx.
300
kHz
Note:
The maximum input frequency only stands for the cutoff frequency of current/voltage converter in PWM 8
(signal source: frequency generator). In real operation with encoders the frequency highly depends on the
photocells and their capacitance, as well as on the cable lengths.
Measure current/voltage:
Measuring range
current:
0 - 500 mA
Measuring range
voltage:
0 - 10 V
Tolerance:
±
3 %
Measure amplitudes:
Measuring range:
2 µApp - 33.3 µApp (0.6 - 10 Vpp)
Measuring frequency:
10 Hz - 50 kHz
Tolerance:
without adjustment via software:
±
5 %
with adjustment via software:
±
3 %
Fault detection signal:
Ie1 and Ie2 < 4 µApp
Encoder output:
Output
signal:
like
input
signal
without U
0
8.5 Specifications of 1Vpp Interface Board
Input amplifier:
Maximum signal voltage:
±
5 Vpp
Maximum frequency at encoder input:
for encoder voltage on interface board:
approx. 500 kHz
for signals on BNC sockets (- 3dB):
approx. 1 MHz
Note:
Input frequencies over 1 MHz are possible; however, the tolerance of the PHA/TV display can no longer be
guaranteed!
The maximum input frequency only stands for the cutoff frequency of the voltage input of PWM 8 (signal
source: frequency generator). In real operation with encoders the frequency highly depends on the encoder
and on the cable lengths.
Measure current/voltage
Measuring range
current:
0 - 500 mA
Measuring range
voltage:
0 - 10 V
Tolerance:
±
3 %