4.4.1 Display of the PWM 8 MODE: MEASURE U/I in the Mode Window


Depending on the power supply of the encoder and of PWM 8, the MODE MEASURE U/I may be displayed
differently in the MODE window:

MODE: MEASURE U/I of encoders with sensor lines
(TTL, HTL, 1Vpp interface boards):

and internally powered encoder (= via power supply unit) or

externally powered encoder and parameter: P2 U-MSYS EXTERN = FLOATING



Floating power supply of the encoder with relation to the
subsequent electronics.

Current consumption of the encoder

Power supply of the encoder
(here: floating)

Sensor lines of the encoder


Special feature of HTL interface board:
A floating power supply of the encoder is not possible. The parameter P2 has no function.
The MODE MEASURE U/I is displayed as follows with HTL interface board:



Special feature of HTL interface board:
The encoder is powered by the power
supply unit (= internally) without potential segregation.


externally powered encoder and parameter: P2 U-MSYS EXTERN = FROM CUSTOMER


The encoder is powered directly by the subsequent
electronics without potential segregation.

Current consumption of the encoder

Power supply of the encoder
(here: customer voltage)

Sensor voltages of the encoder