3 t e st run – HEIDENHAIN iTNC 530 (340 49x-01) User Manual
Page 559
![background image](https://www.manualsdir.com/files/816209/content/doc559.png)
HEIDENHAIN iTNC 530
559
12.3 T
e
st Run
Running a program test
If the central tool file is active, a tool table must be active (status S) to
run a program test. Select a tool table via the file manager (PGM MGT)
in the Test Run mode of operation.
With the MOD function BLANK IN WORK SPACE, you can activate
work space monitoring for the test run (see “Showing the Workpiece
in the Working Space” on page 592).
8
Select the Test Run operating mode
8
Call the file manager with the PGM MGT key and
select the file you wish to test, or
8
Go to the program beginning: Select line “0” with the
GOTO key and confirm your entry with the ENT key.
The TNC then displays the following soft keys:
You can interrupt the program test and continue it again at any point—
even within a machining cycle. In order to continue the test, the
following actions must not be performed:
Selecting another block with the GOTO key
Making changes to the program
Switching the operating mode
Selecting a new program
Function
Soft key
Test the entire program
Test each program block individually
Show the blank form and test the entire program
Interrupt the test run