Fn19: plc: transferring values to the plc, 8 a d ditional f unctions – HEIDENHAIN iTNC 530 (340 49x-01) User Manual
Page 526
![background image](https://www.manualsdir.com/files/816209/content/doc526.png)
526
11 Programming: Q Parameters
1
1
.8 A
d
ditional F
unctions
Example: Assign the value of the active scaling factor for the
Z axis to Q25
FN19: PLC: Transferring values to the PLC
The function FN 19: PLC transfers up to two numerical values or
Q parameters to the PLC.
Increments and units: 0.1 µm or 0.0001°
Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC
36
1
Power ratio for 1st axis
2
Power ratio for 2nd axis
3
Power ratio for 3rd axis
Last touch point in TCH PROBE
Cycle 0 or last touch point from
manual operating mode, 360
1
1 to 9
Position in the active coordinate system in axes 1 to 9
2
1 to 9
Position in the REF system in axes 1 to 9
Value from the active datum table in
the active coordinate system, 500
Datum
number
1 to 9
X axis to W axis
REF value from the active datum
table, 501
Datum
number
1 to 9
X axis to W axis
Datum table selected, 505
1
-
Return code = 0: No datum table active
Return code = 1: Datum table active
Data from the active pallet table, 510
1
-
Active line
2
-
Palette number from PAL/PGM field
Existence of machine parameter,
1010
MP
number
MP index
Return value = 0: MP does not exist
Return code = 1: MP exists
Group name, ID No.
Number
Index
Meaning
55 FN18: SYSREAD Q25 = ID210 NR4 IDX3
56 FN19: PLC=+10/+Q3