beautypg.com

Fn19: plc: transferring values to the plc, 8 a d ditional f unctions – HEIDENHAIN iTNC 530 (340 49x-01) User Manual

Page 526

background image

526

11 Programming: Q Parameters

1

1

.8 A

d

ditional F

unctions

Example: Assign the value of the active scaling factor for the
Z axis to Q25

FN19: PLC: Transferring values to the PLC

The function FN 19: PLC transfers up to two numerical values or
Q parameters to the PLC.

Increments and units: 0.1 µm or 0.0001°

Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC

36

1

Power ratio for 1st axis

2

Power ratio for 2nd axis

3

Power ratio for 3rd axis

Last touch point in TCH PROBE
Cycle 0 or last touch point from
manual operating mode, 360

1

1 to 9

Position in the active coordinate system in axes 1 to 9

2

1 to 9

Position in the REF system in axes 1 to 9

Value from the active datum table in
the active coordinate system, 500

Datum
number

1 to 9

X axis to W axis

REF value from the active datum
table, 501

Datum
number

1 to 9

X axis to W axis

Datum table selected, 505

1

-

Return code = 0: No datum table active
Return code = 1: Datum table active

Data from the active pallet table, 510

1

-

Active line

2

-

Palette number from PAL/PGM field

Existence of machine parameter,
1010

MP
number

MP index

Return value = 0: MP does not exist
Return code = 1: MP exists

Group name, ID No.

Number

Index

Meaning

55 FN18: SYSREAD Q25 = ID210 NR4 IDX3

56 FN19: PLC=+10/+Q3