beautypg.com

Using load monitoring during production, 1 0 load monit o ri ng (option) – HEIDENHAIN SW 68894x-03 User Manual

Page 125

background image

HEIDENHAIN CNC PILOT 640

125

3.1

0

Load monit

o

ri

ng (option)

Using load monitoring during production

During program run, the control monitors the utilization and the total
utilization in each interpolator cycle. In parallel with machining, you can
display a graph of the current utilization values for all monitored axes
of the active zone.

To display the utilization values, select the menu View > Edit load
data
—the control opens the "Set load data" form and additionally
displays the determined values as a bar graph

To display the current utilization values, press the Display active zone
soft key—the control automatically switches to the current monitoring
zone and displays the current utilization values as a bar graph

Keep in mind that you cannot adapt the limit values during
machining. Adapt the limit values before starting a
machining operation.

OPEN DIAGRAM DURING MACHINING

Bar graph
Thick upper bar (display in %)
Green

Current utilization (PA)

Mark in thick upper bar:
Green

Current peak value between 0 and limit value 1 (P)

Yellow

Current peak value between P and limit value 1 (PG1)

Red

Current peak value between PG1 and limit value 2 (PG1)

Thin lower bar (display standardized to reference value 1):
Green

Current total utilization (WA)

Yellow

Current total utilization up to limit value (WGF)