How to increase a timeout for NVEthernetProtocol

When the NV9000 is using nvethernet (np0016 over TCP/IP) to control a router, it is polling the
router every 300 ms and it expects a response from the router within 500 ms. If the NV9000
doesn’t receive the response within 500 ms, SEUtilities will show the router as being offline.

To set the timeout value to a larger custom value

1. In SEUtilities, select Views | Tables | Control Points (see

page 46

).

2. By default, you should see a Parameter entry similar to:

E,10.0.9.39,T500

, where

500

represents the timeout in milliseconds and

10.0.9.39 is the IP address of the router to

control.

3. Edit the value and click Save.

4. Go to System management, select the root node, and then click Write configuration to.

5. Click Restart controller to apply your changes.

How to downgrade a database on a controller

Downgrading NV9000 sometimes involves downgrading the database schema.

How to determine controller version

To determine the NV9000 controller version, click on the System management tab, then
mouse over your controller icon to reveal a tooltip. Version software will be the last item of the
list.

Where to find SE Utilities log file

The system log file is under system management.

How to set up NVISION router

In order to configure a NVISION router, big router with a controller card, you have to run
uniconfig software.

How to set up tie lines

You can configure a tieline with Se-Utilities under configuration tab and tielines. Add
upstream and downstream routers and bind them together by connecting output port to
input port with your mouse.

If you want to free a tieline, click on system management tab, and under tieline status, you
could right click on a tieline and free it.

How to turn on Tieline Manager

Turning on the tieline manager is simply a matter of installing the tieline license and restarting
all the software.

Note: The NV9000 does not accept timeout values smaller than 500 ms.