Grass Valley iRouter v.6.01 User Manual
Page 38
![background image](https://www.manualsdir.com/files/813496/content/doc038.png)
Routing Switchers Tips and Tricks
Network Modular Protocol (Control Protocol for VikinX Modular Routers)
34
Network Modular Protocol (Control Protocol for VikinX Modular Routers)
Please refer to the following document for more information about this protocol:
\\ca-ops-data\Groups\RD
Software\Documentation\iControlRouter\Protocols\Network\VikinX_Control_Protoco
l_rev3.pdf
Select this driver if you wish to use a router controller such as your VikinX Modular router's
SysCon card or an external ETH-CON device.
The Network Modular protocol is an Ethernet ASCII protocol, and uses port 4381.
To confirm the router controller is properly configured
1. Connect to the controller using telnet.
2. In a telnet session, type:
llist
3. Hit Enter twice.
The response will be something like this:
4. To get the status of all the crosspoints on a level, type
s l
, and then press Enter
twice.
The response will have the following form:
x l