Chapter 2 - Installation

Voltage level send lead

* isolated from ground.

Open / Voltage level send lead

* isolated from ground.

Figure 2-19. Voltage level signalling

Table 2-17. Voltage level Send lead (0 to 2.5 VDC, 4 to 24 VDC)*

Menu setting

Input 0 to 2.5 V

Input 4 to 24 V

LH

Function ON

Function OFF

HL

Function OFF

Function ON

Table 2-18. Open / voltage level Send lead (open, 4 to 24 VDC)*

Menu setting

Input open

Input 4 to 24 V

OH

Function ON

Function OFF

HO

Function OFF

Function ON

+5 - 24 VDC

External
signaling
with DC
output
voltage

+

Base Station

signalling

connector