Verify the configurations – H3C Technologies H3C S10500 Series Switches User Manual
Page 38
29
[DeviceE] cfd meplist 1001 4002 5001 service-instance 1
[DeviceE] interface gigabitethernet 1/0/4
[DeviceE-GigabitEthernet1/0/4] cfd mep 5001 service-instance 1 inbound
[DeviceE-GigabitEthernet1/0/4] cfd mep service-instance 1 mep 5001 enable
[DeviceE-GigabitEthernet1/0/4] quit
5.
Configure MIPs.
# Configure the MIP generation rule in service instance 1 on Device B as explicit.
[DeviceB] cfd mip-rule explicit service-instance 1
# Configure the MIP generation rule in service instance 2 on Device C as default.
[DeviceC] cfd mip-rule default service-instance 2
6.
Configure CC.
# On Device A, enable the sending of CCM frames for MEP 1001 in service instance 1 on
GigabitEthernet 1/0/1.
[DeviceA] interface gigabitethernet 1/0/1
[DeviceA-GigabitEthernet1/0/1] cfd cc service-instance 1 mep 1001 enable
[DeviceA-GigabitEthernet1/0/1] quit
# On Device B, enable the sending of CCM frames for MEP 2001 in service instance 2 on
GigabitEthernet 1/0/3.
[DeviceB] interface gigabitethernet 1/0/3
[DeviceB-GigabitEthernet1/0/3] cfd cc service-instance 2 mep 2001 enable
[DeviceB-GigabitEthernet1/0/3] quit
# On Device D, enable the sending of CCM frames for MEP 4001 in service instance 2 on
GigabitEthernet 1/0/1, and enable the sending of CCM frames for MEP 4002 in service instance 1 on
GigabitEthernet 1/0/3.
[DeviceD] interface gigabitethernet 1/0/1
[DeviceD-GigabitEthernet1/0/1] cfd cc service-instance 2 mep 4001 enable
[DeviceD-GigabitEthernet1/0/1] quit
[DeviceD] interface gigabitethernet 1/0/3
[DeviceD-GigabitEthernet1/0/3] cfd cc service-instance 1 mep 4002 enable
[DeviceD-GigabitEthernet1/0/3] quit
# On Device E, enable the sending of CCM frames for MEP 5001 in service instance 1 on
GigabitEthernet 1/0/4.
[DeviceE] interface gigabitethernet 1/0/4
[DeviceE-GigabitEthernet1/0/4] cfd cc service-instance 1 mep 5001 enable
[DeviceE-GigabitEthernet1/0/4] quit
Verify the configurations
1.
Verify the LB function.
When the CC function detects a link fault, use the LB function to locate the fault.
# Enable LB on Device A to check the status of the link between MEP 1001 and MEP 5001 in service
instance 1.
[DeviceA] cfd loopback service-instance 1 mep 1001 target-mep 5001
Loopback to 0010-FC00-6515 with the sequence number start from 1001-43404:
Reply from 0010-FC00-6515: sequence number=1001-43404 time=5ms
Reply from 0010-FC00-6515: sequence number=1001-43405 time=5ms
Reply from 0010-FC00-6515: sequence number=1001-43406 time=5ms
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS