H3C Technologies H3C S10500 Series Switches User Manual
Page 125
116
# Create MA MA_A for the MD and configure the MA to serve VLAN 10, and create service instance 1
for the MD and MA.
[DeviceC] cfd ma MA_A md MD vlan 10
[DeviceC] cfd service-instance 1 md MD ma MA_A
# Create a MEP list in service instance 1, create and enable outward-facing MEP 1001, and enable CCM
sending in service instance 1 on GigabitEthernet 1/0/1.
[DeviceC] cfd meplist 1001 1002 service-instance 1
[DeviceC] interface gigabitethernet 1/0/1
[DeviceC-GigabitEthernet1/0/1] cfd mep 1001 service-instance 1 outbound
[DeviceC-GigabitEthernet1/0/1] cfd mep service-instance 1 mep 1001 enable
[DeviceC-GigabitEthernet1/0/1] cfd cc service-instance 1 mep 1001 enable
[DeviceC-GigabitEthernet1/0/1] quit
# Create MA MA_B for the MD and configure the MA to serve VLAN 110, and create service instance
2 for the MD and MA.
[DeviceC] cfd ma MA_B md MD vlan 110
[DeviceC] cfd service-instance 2 md MD ma MA_B
# Create a MEP list in service instance 2, create and enable outward-facing MEP 2001, and enable
CCM sending in service instance 2 on GigabitEthernet 1/0/2.
[DeviceC] cfd meplist 2001 2002 service-instance 2
[DeviceC] interface gigabitethernet 1/0/2
[DeviceC-GigabitEthernet1/0/2] cfd mep 2001 service-instance 2 outbound
[DeviceC-GigabitEthernet1/0/2] cfd mep service-instance 2 mep 2001 enable
[DeviceC-GigabitEthernet1/0/2] cfd cc service-instance 2 mep 2001 enable
[DeviceC-GigabitEthernet1/0/2] quit
# Configure the collaboration between the master port GigabitEthernet 1/0/1 of smart link group 1 and
the CC function of CFD, and bring up the port.
[DeviceC] interface gigabitethernet 1/0/1
[DeviceC-GigabitEthernet1/0/1] port smart-link group 1 track cfd cc
[DeviceC-GigabitEthernet1/0/1] undo shutdown
[DeviceC-GigabitEthernet1/0/1] quit
# Configure the collaboration between the master port GigabitEthernet 1/0/2 of smart link group 2 and
the CC function of CFD, and bring up the port.
[DeviceC] interface gigabitethernet 1/0/2
[DeviceC-GigabitEthernet1/0/1] port smart-link group 2 track cfd cc
[DeviceC-GigabitEthernet1/0/2] undo shutdown
[DeviceC-GigabitEthernet1/0/2] quit
4.
Configure Device D.
# Create VLAN 1 through VLAN 200.
[DeviceD] vlan 1 to 200
# Configure GigabitEthernet 1/0/1 as a trunk port and assign it to VLANs 1 through 200. Enable flush
message receiving and configure VLAN 10 and VLAN 110 as the receive control VLANs on
GigabitEthernet 1/0/1.
[DeviceD] interface gigabitethernet 1/0/1
[DeviceD-GigabitEthernet1/0/1] port link-type trunk
[DeviceD-GigabitEthernet1/0/1] port trunk permit vlan 1 to 200
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS