Collaboration between smart link and cc of cfd, Smart link configuration task list – H3C Technologies H3C S10500 Series Switches User Manual
Page 108
99
function to monitor the uplink ports of the upstream devices. Monitor Link adapts the up/down state of
downlink ports to the up/down state of uplink ports, triggering Smart Link to perform link switchover on
the downstream device.
NOTE:
For more information about Monitor Link, see the chapter “Monitor Link configuration.”
Collaboration between Smart Link and CC of CFD
Smart Link cannot sense by itself when faults (for example, unidirectional link, misconnected fibers, and
packet loss) occur on the intermediate devices or network paths, or when faults are cleared. To check the
link status, Smart Link ports must use link detection protocols. When a fault is detected or cleared, the link
detection protocols inform Smart Link to switch over the links.
With the collaboration between Smart Link and the Continuity Check (CC) function of Connectivity Fault
Detection (CFD) configured, CFD notifies the ports of fault detection events on the basis of detection
VLANs and detection ports. A port responds to a continuity check event only when the control VLAN of
the smart link group to which it belongs matches the detection VLAN.
NOTE:
For more information about the CC function of CFD, see the chapter “CFD configuration.”
Smart Link configuration task list
Complete the following tasks to configure Smart Link:
Task
Remarks
Configuring protected VLANs for a smart link
group
Required
Configuring member ports for a smart link group
Required
Configuring role preemption for a smart link
group
Optional
Enabling the sending of flush messages
Optional
Configuring a Smart Link device
Configuring the collaboration between Smart
Link and CC of CFD
Optional
Configuring an associated device
Enabling the receiving of flush messages
Required
NOTE:
•
A smart link device is a device that supports Smart Link and is configured with a smart link group and
a transmit control VLAN for flush message transmission. Device C and Device D in
are two
examples of smart link devices.
•
An associated device is a device that supports Smart Link and receives flush messages sent from the
specified control VLAN. Device A, Device B, and Device E in
are examples of associated
devices.
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS