H3C Technologies H3C S10500 Series Switches User Manual
Page 119
110
[DeviceC-smlk-group1] port gigabitethernet1/0/2 slave
# Enable role preemption in smart link group 1, enable flush message sending, and configure VLAN 10
as the transmit control VLAN.
[DeviceC-smlk-group1] preemption mode role
[DeviceC-smlk-group-1] flush enable control-vlan 10
[DeviceC-smlk-group-1] quit
# Create smart link group 2, and configure all VLANs mapped to MSTI 2 as the protected VLANs for
smart link group 2.
[DeviceC] smart-link group 2
[DeviceC-smlk-group2] protected-vlan reference-instance 2
# Configure GigabitEthernet 1/0/1 as the slave port and GigabitEthernet 1/0/2 as the master port for
smart link group 2.
[DeviceC-smlk-group2] port gigabitethernet1/0/2 master
[DeviceC-smlk-group2] port gigabitethernet1/0/1 slave
# Enable role preemption in smart link group 2, enable flush message sending, and configure VLAN 110
as the transmit control VLAN.
[DeviceC-smlk-group2] preemption mode role
[DeviceC-smlk-group2] flush enable control-vlan 110
[DeviceC-smlk-group2] quit
# Bring up GigabitEthernet 1/0/1 and GigabitEthernet 1/0/2 again.
[DeviceC] interface gigabitethernet 1/0/1
[DeviceC-GigabitEthernet1/0/1] undo shutdown
[DeviceC-GigabitEthernet1/0/1] quit
[DeviceC] interface gigabitethernet 1/0/2
[DeviceC-GigabitEthernet1/0/2] undo shutdown
[DeviceC-GigabitEthernet1/0/2] quit
2.
Configure Device B.
# Create VLAN 1 through VLAN 200.
[DeviceB] vlan 1 to 200
# Configure GigabitEthernet 1/0/1 as a trunk port and assign it to VLANs 1 through 200. Enable flush
message receiving and configure VLAN 10 and VLAN 110 as the receive control VLANs on
GigabitEthernet 1/0/1.
[DeviceB] interface gigabitethernet 1/0/1
[DeviceB-GigabitEthernet1/0/1] port link-type trunk
[DeviceB-GigabitEthernet1/0/1] port trunk permit vlan 1 to 200
[DeviceB-GigabitEthernet1/0/1] smart-link flush enable control-vlan 10 110
[DeviceB-GigabitEthernet1/0/1] quit
# Configure GigabitEthernet 1/0/2 as a trunk port and assign it to VLANs 1 through 200. Disable the
spanning tree feature and enable flush message receiving on it, and configure VLAN 10 and VLAN 110
as the receive control VLANs.
[DeviceB] interface gigabitethernet 1/0/2
[DeviceB-GigabitEthernet1/0/2] port link-type trunk
[DeviceB-GigabitEthernet1/0/2] port trunk permit vlan 1 to 200
[DeviceB-GigabitEthernet1/0/2] undo stp enable
[DeviceB-GigabitEthernet1/0/2] smart-link flush enable control-vlan 10 110
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS