Link monitoring – H3C Technologies H3C S10500 Series Switches User Manual
Page 19
10
Table 6 Active Ethernet OAM mode and passive Ethernet OAM mode
Item
Active Ethernet OAM mode
Passive Ethernet OAM mode
Initiating OAM Discovery
Available
Unavailable
Responding to OAM Discovery
Available
Available
Transmitting Information
OAMPDUs
Available Available
Transmitting Event Notification
OAMPDUs
Available Available
Transmitting Information
OAMPDUs without any TLV
Available Available
Transmitting Loopback Control
OAMPDUs
Available Unavailable
Responding to Loopback Control
OAMPDUs
Available—if both sides operate in
active OAM mode
Available
NOTE:
•
Only OAM entities operating in active OAM mode can initiate OAM connections. OAM entities
operating in passive mode wait and respond to the connection requests sent by their peers.
•
No OAM connection can be established between OAM entities operating in passive OAM mode.
After an Ethernet OAM connection is established, the Ethernet OAM entities on both sides exchange
Information OAMPDUs at a specified interval—handshake packet transmission interval—to check
whether the Ethernet OAM connection is normal. If an Ethernet OAM entity receives no Information
OAMPDU within the Ethernet OAM connection timeout time, the Ethernet OAM connection is considered
disconnected.
Link monitoring
Error detection in an Ethernet is difficult, especially when the physical connection in the network is not
disconnected but network performance is degrading gradually. Link monitoring is used to detect and
indicate link faults in various environments. Ethernet OAM implements link monitoring through the
exchange of Event Notification OAMPDUs. When detecting one of the link error events listed in
the local OAM entity sends an Event Notification OAMPDU to notify the remote OAM entity. With the
log information, network administrators can keep track of network status promptly.
Table 7 Ethernet OAM link error events
Ethernet OAM link events
Description
Errored symbol event
An errored symbol event occurs when the number of detected symbol
errors during a specified detection interval exceeds the predefined
threshold.
Errored frame event
An errored frame event occurs when the number of detected error
frames during a specified interval exceeds the predefined threshold.
Errored frame period event
An errored frame period event occurs if the number of frame errors in
a specific number of received frames exceeds the predefined
threshold.
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS