How ethernet oam works, Ethernet oam connection establishment – H3C Technologies H3C S10500 Series Switches User Manual
Page 18
9
Table 4 The fields in an OAMPDU
Field Description
Dest addr
Destination MAC address of the Ethernet OAMPDU
It is a slow protocol multicast address, 0180c2000002. Bridges cannot forward
slow protocol packets, so Ethernet OAMPDUs cannot be forwarded.
Source addr
Source MAC address of the Ethernet OAMPDU
It is the bridge MAC address of the sending side and is a unicast MAC address.
Type
Type of the encapsulated protocol in the Ethernet OAMPDU
The value is 0x8809.
Subtype
The specific protocol being encapsulated in the Ethernet OAMPDU
The value is 0x03.
Flags
Status information of an Ethernet OAM entity
Code
Type of the Ethernet OAMPDU
NOTE:
Throughout this document, a port with Ethernet OAM enabled is an Ethernet OAM entity or an OAM
entity.
Table 5 Functions of different types of OAMPDUs
OAMPDU type
Function
Information OAMPDU
Used for transmitting state information of an Ethernet OAM entity—including the
information about the local device and remote devices and customized
information—to the remote Ethernet OAM entity and maintaining OAM connections.
Event Notification
OAMPDU
Used by link monitoring to notify the remote OAM entity when it detects problems on
the link in between
Loopback Control
OAMPDU
Used for remote loopback control. By inserting the information used to
enable/disable loopback to a loopback control OAMPDU, you can enable/disable
loopback on a remote OAM entity.
How Ethernet OAM works
This section describes the working procedures of Ethernet OAM.
Ethernet OAM connection establishment
Ethernet OAM connection is the basis of all the other Ethernet OAM functions. OAM connection
establishment is also known as the “Discovery phase”, where an Ethernet OAM entity discovers remote
OAM entities and establishes sessions with them.
In this phase, interconnected OAM entities determine whether Ethernet OAM connections can be
established, by exchanging Information OAMPDUs to notify the peer of their OAM configuration
information and the OAM capabilities of the local nodes. An Ethernet OAM connection can be
established between entities that have matching Loopback, link detecting, and link event settings. After
an Ethernet OAM connection is established, Ethernet OAM takes effect on both sides.
For Ethernet OAM connection establishment, a device can operate in active Ethernet OAM mode or
passive Ethernet OAM mode, but a switch role will be somewhat different depending on the mode.
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS