Associating track with nqa, Associating track with bfd – H3C Technologies H3C S10500 Series Switches User Manual
Page 178
169
Task Remarks
Associating the track module
with a detection module
Associating track with interface management
Required
Use any of the
approaches.
Associating track with static routing
Associating the track module
with an application module
Required
Use any of the
approaches.
Associating the track module with a detection
module
Associating track with NQA
NQA supports multiple test types to analyze network performance, services, service quality. For example,
an NQA test group can periodically detect whether a destination is reachable, or whether the TCP
connection to a TCP server can be set up.
An NQA test group functions as follows when it is associated with a track entry:
•
If the consecutive failures reach the specified threshold, the NQA module tells the track module that
the tracked object malfunctions. Then the track module sets the track entry to the Negative state.
•
If the specified threshold is not reached, the NQA module tells the track module that the tracked
object functions normally. The track module then sets the track entry to the Positive state.
For more information about NQA, see Network Management and Monitoring Configuration Guide.
Follow these steps to associate track with NQA:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Create a track entry, associate it
with an NQA reaction entry, and
specify the delay time for the track
module to notify the associated
application module when the track
entry status changes
track track-entry-number nqa entry
admin-name operation-tag reaction
item-number [ delay { negative
negative-time | positive
positive-time } * ]
Required
No track entry is created by
default.
NOTE:
If the specified NQA test group or the reaction entry in the track entry does not exist, the status of the track
entry is Invalid.
Associating track with BFD
BFD supports the control packet mode and echo mode. Only echo-mode BFD can be associated with a
track entry.
The BFD functions as follows when it is associated with a track entry:
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS