Configuring BFD basic functions
The BFD basic functions configuration is the basis for configuring BFD for other protocols.
Configuration prerequisites
Before configuring BFD basic functions, complete the following tasks:
•
Configure the network layer addresses of the interfaces so that adjacent nodes are reachable to
each other at the network layer
•
Configure the routing protocols that support BFD
Configuration procedure
Follow these steps to configure BFD basic functions:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Specify the mode for establishing a
BFD session
bfd session init-mode { active |
passive }
Optional
active by default
Configure the destination port
number for multi-hop BFD control
packets
bfd multi-hop destination-port
port-number
Optional
4784 by default.
Configure the source IP address of
echo packets
bfd echo-source-ip ip-address
Optional
The source IP address should not
be on the same network segment
as any local interface’s IP address.
Otherwise, a large number of
ICMP redirect packets may be sent
from the peer, resulting in link
congestion.
Enter interface view
interface interface-type
interface-number
—
Configure the minimum interval for
receiving BFD echo packets
bfd min-echo-receive-interval
value
Optional
For relevant information, see the
description of the Required Min
Echo RX Interval field in “
400 milliseconds by default
Configure the minimum interval for
transmitting BFD control packets
bfd min-transmit-interval value
Optional
For relevant information, see the
description of the Desired Min TX
Interval field in “
.”
400 milliseconds by default
- H3C S5800 Series Switches H3C S5820X Series Switches H3C WX3000E Series Wireless Switches H3C SecPath F1000-E H3C SecPath F5000-A5 Firewall H3C SecPath F1000-A-EI H3C SecPath F1000-E-SI H3C SecPath F1000-S-AI H3C SecPath F5000-S Firewall H3C SecPath F5000-C Firewall H3C SecPath F100-C-SI H3C SecPath F1000-C-SI H3C SecPath F100-A-SI H3C SecBlade FW Cards H3C SecBlade FW Enhanced Cards H3C SecPath U200-A U200-M U200-S H3C SecPath U200-CA U200-CM U200-CS