beautypg.com

Delta Electronics Extension Digital I/O Module DOP-EXIO14RAE User Manual

Page 140

background image

Appendix D Use of Application Instructions|DOP-EXIO Series

Revision March, 2008, Doc. Name: 2007PDD23000014

D-59

Mnemonic

Operands Function

ALT

D

Alternate State

Bit Devices

Word Devices

X Y M S K H

KnX

KnY

KnM KnS

T

C

D

E

F

D

16-bit instruction (3 Steps)

ALT

Continuous
execution

32-bit instruction

- -

- -

y

Flags: None

Operands:

D

: Destination device

Program Example 1:
When X0 goes from Off to On for the first time, Y0 will be On. When X0 goes from Off to On for the
second time, Y0 will be Off.

X0

ALTP

Y0

X0

Y0

Program Example 2:
Using a single switch to enable and disable control. At the beginning, M0 = Off, so Y0 = On and Y1 =
Off. When X10 switches between On/Off for the first time, M0 will be On, so Y1 = On and Y0 = Off. For
the second time of On/Off switching, M0 will be Off, so Y0 = On and Y1 = Off.

X10

ALT

M0

M0

Y0

M0

Y1

Program Example 3:
Generating flashing. When X10 = On, T0 will generate a pulse every 2 seconds and Y0 output will
switch between On and Off following the T0 pulses.