beautypg.com

Delta Electronics Extension Digital I/O Module DOP-EXIO14RAE User Manual

Page 119

background image

Appendix D Use of Application Instructions|DOP-EXIO Series

D-38

Revision March, 2008, Doc. Name: 2007PDD23000014

Mnemonic

Operands Function

DEC

D

D

BIN 減一

Bit Devices

Word Devices

X Y M S K H

KnX

KnY

KnM KnS

T

C

D

E

F

D

y

Note:

1. If D is used in device F, only 16-bit instruction is applicable.

16-bit instruction (3 Steps)

DEC

Continuous
execution

32-bit instruction (5 Steps)

DDEC

Continuous
execution

y

Flags: None

Operands:

D

: Destination device

Explanations:
1. If the instruction is not a pulse execution one, the content in the designated device D will minus

“1” in every scan period whenever the instruction is executed.

2. In 16-bit operation, -32,768 minuses 1 and obtains 32,767. In 32-bit operation, -2,147,483,648

minuses 1 and obtains 2,147,483,647.

3. The operation results will not affect any flags.

Program Example:
When X0 = Off→On, the content in D0 minuses 1 automatically.

X0

DECP

D0