User module »DVI-CON-Fiber«

70 · Target and user modules

Connection to the matrix switch

Transmission |Tx:

Insert the LC plug of an optical fibre cable.

Connect the other end of the cable to the

Rx

interface of a compatible Dynamic Port

provided at the matrix switch.

Transmission|Rx:

Insert the LC plug of an optical fibre cable.

Connect the other end of the cable to the

Tx

interface of the same Dynamic Ports pro-

vided at the matrix switch.

Power supply

Main Power:

Connect the power cable with the power pack and a power socket.

Red. Power:

Connect the cable of the optional power pack to establish a redundant

power supply. Connect the power cable with the power pack and a power socket of

another power circuit.

Start-up

Turn on the power button of the Main Power power pack.

The devices use components with laser technology which comply with laser

class 1.

They meet the requirements according to

EN 60825-1:2007

and

EN 60825-

2:2004+A1:2007

as well as

U.S. CFR 1040.10

and

1040.11

.

Mind the following instructions when dealing with laser beams:

Avoid eye contact with invisible laser beam on page 2

Always connect optical connections or cover them with protection caps on page 2

Only use G&D certified transmission modules on page 2

NOTE:

Use optical fibres with LC plugs to connect the devices. The cables are avail-

able as accessories.

ADVICE:

You can also connect the target module directly to a compatible user mod-

ule.

ADVICE:

During the System Startup of the suer module. the current hotkey configu-

ration of the matrix switch is shown.