Status displays, Front panel – Guntermann & Drunck DVICenter DP16 Target Modules and User Modules - Standard Variants User Manual
Page 68

User module »DVI-CON-MC4«
64 · Target and user modules
Status displays
Front panel
Section
LED
Status Meaning
Power
Red.
On
The optional power pack is connected and supplies 12 Volt.
Off
The optional power pack is not (properly) connected.
Main
On
The power pack is turned on and supplies the required
voltage.
Off
The power pack is turned off or the connection to the mains
could not be established.
Status
Trans. 1
On
The communication to the matrix switch is established success-
fully.
Off
The communication to the matrix switch could not be estab-
lished.
System
On
Device boots or firmware update is executed.
Flash-
ing
System is ready for operation.
Console Video 1
On
Strong video signal at first video input.
Off
No signal at first video input, or the signal quality is too weak to
be processed by the system.
K/M
On
A local keyboard was detected.
Off
No power at PS/2 interface or USB bus.
Flash-
ing
The CPU input (PS/2 or USB) is active and ready.
A local keyboard was not detected.
MC2
Video 2
On
Strong video signal at second video input.
Off
No signal at second video input, or the signal quality is too
weak to be processed by the system.
Trans. 2
On
The communication to the matrix switch is established success-
fully.
Off
The communication to the matrix switch could not be estab-
lished.
- DVICenter DP32 Target Modules and User Modules - Standard Variants DVICenter DP64 Target Modules and User Modules - Standard Variants DVICenter DP16 Target Modules and User Modules - Integrated USB DVICenter DP32 Target Modules and User Modules - Integrated USB DVICenter DP64 Target Modules and User Modules - Integrated USB