Connection to the matrix switch, Power supply, Startup – Guntermann & Drunck DVICenter DP16 Target Modules and User Modules - Standard Variants User Manual
Page 59

User module »DVI-CON-MC2«
Target and user modules · 55
Connection to the matrix switch
Transmission 1:
Connect this interface to a Dynamic Port (RJ45) of the matrix switch.
Transmission 2:
Connect this interface to another Dynamic Port (RJ45) of the matrix
switch.
Power supply
Main Power:
Connect the supplied power cable.
Insert the cable’s Schuko plug in a power socket.
Red. Power:
Connect the connection cable of a compatible power pack to provide the
user module with a second, redundant power supply.
Startup
Turn on the user module after its installation.
Use the
Main Power
power pack or a redundant power pack to establish the power
supply:
Turn on the
Main Power
power pack.
Use an optional power pack to supply the
Red. Power
socket with power.
NOTE:
Use category 5e (or better) twisted pair cables to connect the devices.
NOTE:
You can also connect the target module directly to a compatible target module.
Keyb./Mouse
Generic
Transmission 1
Micro In
Red. Power
DVI / VGA Out 1
LED out
Speaker
Mouse
Keyb.
Transmission 2
DVI / VGA Out 2
- DVICenter DP32 Target Modules and User Modules - Standard Variants DVICenter DP64 Target Modules and User Modules - Standard Variants DVICenter DP16 Target Modules and User Modules - Integrated USB DVICenter DP32 Target Modules and User Modules - Integrated USB DVICenter DP64 Target Modules and User Modules - Integrated USB