beautypg.com

Connection to the matrix switch, Power supply – Guntermann & Drunck DVICenter DP16 Target Modules and User Modules - Standard Variants User Manual

Page 33

background image

Target module »DVI-CPU-Fiber-UC«

Target and user modules · 29

Connection to the matrix switch

Trans. 1|Tx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Rx

interface of a Dynamic Port provided at

the first matrix switch.

Trans. 1|Rx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Tx

interface of the same Dynamic Port pro-

vided at the first matrix switch.

Trans. 2|Tx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Rx

interface of a Dynamic Port provided at

the second matrix switch.

Trans. 2|Rx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Tx

interface of the same Dynamic Port pro-

vided at the second matrix switch.

Power supply

Power In:

Connect the cable of the power pack to this interface. Now connect the

power cable to the power pack and a power socket.

The devices use components with laser technology which comply with laser

class 1.

They meet the requirements according to

EN 60825-1:2007

and

EN 60825-

2:2004+A1:2007

as well as

U.S. CFR 1040.10

and

1040.11

.

Mind the following instructions when dealing with laser beams:

Avoid eye contact with invisible laser beam on page 2

Always connect optical connections or cover them with protection caps on page 2

Only use G&D certified transmission modules on page 2

NOTE:

Use optical fibres with LC plugs to connect the devices. The cables are avail-

able as accessories.

IMPORTANT:

For each matrix switch, connect only one Trans. interface of the tar-

get module!

ADVICE:

You can also connect the target module directly to a compatible user mod-

ule.