background image

Target module »DVI-CPU-Fiber«

24 · Target and user modules

Connection to the matrix switch

Trans.|Tx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Rx

interface of a Dynamic Port provided at

the first matrix switch.

Trans.|Rx:

Insert the LC plug of a compatible optical fibre cable.

Connect the other end of the cable to the

Tx

interface of the same Dynamic Port pro-

vided at the first matrix switch.

Power supply

Power In:

Connect the cable of the power pack to this interface. Now connect the

power cable to the power pack and a power socket.

The devices use components with laser technology which comply with laser

class 1.

They meet the requirements according to

EN 60825-1:2007

and

EN 60825-

2:2004+A1:2007

as well as

U.S. CFR 1040.10

and

1040.11

.

Mind the following instructions when dealing with laser beams:

Avoid eye contact with invisible laser beam on page 2

Always connect optical connections or cover them with protection caps on page 2

Only use G&D certified transmission modules on page 2

NOTE:

Use optical fibres with LC plugs to connect the devices. The cables are avail-

able as accessories.

ADVICE:

You can also connect the target module directly to a compatible user mod-

ule.