Page 17: Automatic grouping of channels

background image

Target module »DVI-CPU-MC2«

Target and user modules · 13

Connection to the matrix switch

Trans.|Channel 1:

Connect this interface to a Dynamic Port (RJ45) of the matrix

switch.

Trans.|Channel 2:

Connect this interface to another Dynamic Port (RJ45) of the matrix

switch.

Power supply

Power In:

Insert the power pack’s connection cable to this interface.

Start-up

Connect the power cable to the power pack and a power socket.

The target module starts as soon as it is supplied with power. During start-up, the

channels are automatically grouped (see below).

Automatic grouping of channels

When operating the target module for the first time, the matrix switch recognises the

main channel and the target module’s additional channel. The channels are automat-

ically added to a channel group.

The web application uses the following icons to mark the different types of channels:

Main channel:

target module icon with »

MC

« lettering

Video channel:

target module icon with blue spot

In the web application, the list of target modules provides separate entries for
grouped channels. The icon next to the module name shows that the module is

part of a channel group.

Click the icon to get information about the channel group.

NOTE:

Only use category 5e (or better) twisted pair cables to connect the devices.

NOTE:

You can also connect the target directly to a compatible user module.

NOTE:

In addition to the data of the KVM main channel, a channel group transmits

up to seven additional video channels and/or one USB 2.0 or RS 232 channel.

NOTE:

You can adjust any channel groups that were created automatically or

manually. More information about channel groups is given in the separate manu-