Connection to the matrix switch, Power supply, Start-up – Guntermann & Drunck DVICenter DP16 Target Modules and User Modules - Standard Variants User Manual
Page 53

User module »DVI-CON«
Target and user modules · 49
Connection to the matrix switch
Transmission:
Use a category 5e (or better) twisted pair cable to connect the Transmis-
sion interface to a Dynamic Port (RJ45) of the matrix switch.
Power supply
Main Power:
Connect the power cable to the power pack and a power outlet.
Red. Power:
If required, connect the power cable of the optional power pack to this
interface. This provides a redundant power supply. Connect the power cable with
the power pack and a power outlet of a different power circuit.
LED Out:
If you expanded the functional range of the matrix switch by purchasing the
TradeSwitch function, connect the optional TS-LED-2 (order number A6100041) to this
interface.
Start-up
Start the user module by pressing the Main Power button of the power pack.
NOTE:
You can also connect the target module directly to a compatible user module.
ADVICE:
The active hotkey configuration is displayed during the System Startup of
the matrix switch.
- DVICenter DP32 Target Modules and User Modules - Standard Variants DVICenter DP64 Target Modules and User Modules - Standard Variants DVICenter DP16 Target Modules and User Modules - Integrated USB DVICenter DP32 Target Modules and User Modules - Integrated USB DVICenter DP64 Target Modules and User Modules - Integrated USB