beautypg.com

In step, Caution – Gasboy ATC M05819K00X Kits User Manual

Page 26

background image

Installing the Commercial Atlas (9800K) ATC Kits

Page 26

MDE-4431C Gasboy ATC M05819K00X Kits Installation Manual · February 2013

34

Under the shelf (where the IS Barrier is mounted), locate the two plugs in the hydraulic
coupling toward the right side of the unit (see

Figure 19

).

Figure 19: Hydraulic Coupling (Probe Assembly Mounting Location)

Probe Assembly

Holes plugged when
Probe is not installed

Adapter

Thermowell Plug

Thermowell

35

Remove the two plugs using an appropriate size Allen-wrench.

When applying SAF-T-LOK TPS Sealant on threads, leave the two threads that
enter the hole first free of sealant to prevent the sealant from entering, and
possibly damaging or inhibiting proper operation of the unit.

CAUTION

36

Coat the Thermowell Threads (BC407) using SAF-T-LOK TPS Sealant and thread into one of
the holes where the plugs were removed in step

35

(see

Figure 19

).

37

Tighten the Thermowell using a proper size wrench and place the 235-C Thermowell Plug into
the Thermowell.

38

Coat the threads of the Adapter (BC546) with SAF-T-LOK TPS Sealant and turn it into the
other hole where the plugs were removed (see

Figure 19

).

39

Coat the threads of the Probe Assembly (W199) with SAF-T-LOK TPS Sealant and turn it into
the Adapter (BC546) mounted in step

38

.