Caution – Gasboy ATC M05819K00X Kits User Manual
Page 18

Installing the Commercial Atlas (9800K) ATC Kits
Page 18
MDE-4431C Gasboy ATC M05819K00X Kits Installation Manual · February 2013
34
Under the shelf (where the IS Barrier Stud is secured), locate the two plugs in the hydraulic
coupling (see
Figure 11: Hydraulic Coupling (Probe Assembly Mounting Location)
Probe Assembly
Holes plugged when Probe is not
installed
Adapter
Thermowell Plug
Thermowell
35
When applying SAF-T-LOK
®
TPS Sealant on threads, leave the two threads that
enter the hole first free of sealant to prevent the sealant from entering, and
possibly damaging or inhibiting proper operation of the unit.
CAUTION
Remove the two plugs using an appropriate size Allen-wrench.
36
Coat the Thermowell Threads (BC407) with SAF-T-LOK TPS Sealant and threads into one of
the holes where the plugs were removed in step
37
Tighten the Thermowell using a proper size wrench and place the Thermowell Plug (235-C)
into the Thermowell.
38
Coat the threads of the Adapter (BC546) with SAF-T-LOK TPS Sealant and turn it into the
other hole where the plugs were removed in step
).
39
Coat the threads of the Probe Assembly (W199) with SAF-T-LOK TPS Sealant and turn it into
the Adapter (BC546) mounted in step
on