beautypg.com

Gasboy ATC M05819K00X Kits User Manual

Page 17

background image

MDE-4431C Gasboy ATC M05819K00X Kits Installation Manual · February 2013

Page 17

Installing the Commercial Atlas (9800K) ATC Kits

29

In the Polycase Box (LP-70), locate the DIP Switches shown in

Figure 9

on

page 15

and set

the switches for the proper unit as shown in the following table.

DIP Switch Settings

Switch
Number

Switch
Function

Settings for Existing and Model
9850K

Settings for Models

9840K, 9852K, 9853K

1

Product 1

ON for Diesel, OFF for Gasoline

ON for Diesel, OFF for Gasoline

2

Product 2

ON for Diesel, OFF for Gasoline

ON for Diesel, OFF for Gasoline

3

Not used

N/A

N/A

4

Unit of Measure N/A

ON for Liters, OFF for Gallons

5

Pulser Multiplier ON for 9850 and 9850K, OFF for

9852/9853

N/A

6

Number of
Probes

ON for two (2) probes, OFF for one (1)
probe

ON for two (2) probes, OFF for one (1)
probe

7

Pulser Adder

ON for 9840

ON for 9840K

8

ATC

ON for ATC ON, OFF for ATC OFF

ON for ATC ON, OFF for ATC OFF

30

Remount the Polycase Box (LP-70) cover removed in step

1

on

page 10

.

31

Using two of the crimp splices, connect the two yellow wires extending from the bottom of the
IS Barrier Mounting Stud to the two blue wires attached to the Single Probe Connector
Assembly.

32

Cap the end of the two green wires extending from the bottom of the IS barrier, using two
Caps (0M0205) or suitable size wire nuts (these are not part of the kit).

33

Locate the following parts provided in the kit (for parts identification, see

Figure 1

on

page 5

):

• Probe Assembly (W199)
• Thermowell (BC407)
• Thermowell Plug (235-C)
• Adapter (BC546)