Onfiguration, Configuration tab – DC Power Technologies Charger Interface Software Manual User Manual
Page 9

8
© 2014 Enatel Motive Power Ltd. Specifications subject to change without prior notice. Errors
exempt. Pictures may be representative, actual products may differ.
2.4. Configuration Tab
The Configuration tab allows the charger configuration to be viewed, modified
and saved back to the charger.
Uses:
View or edit charger configuration depending on access level.
Print charger rating label using configuration parameters.
Configure Auto Equalise, Daily Charging Schedule, Start Time Delay, Cool Down
Timer. Set charger internal clock.
Section Overview:
Configuration Template
Select battery, charger model and
AC supply type to generate the
charger
configuration
automatically. A CSV file with the
appropriate parameters must first
be loaded using the Import CSV
button.
Charger Configuration
View the current configuration of
the charger, print a rating label.
Changing these options requires
Configuration access.
Print Label
Print a rating label once the
charger is configured. Options for
what parameters to print and print
designation are available.
Auto Equalise Settings
Set the charger to perform equalise
charges according to defined rules:
profile, cycle or time based.
Requires Configuration access.
Auto Watering Settings
Set duration and number of charge
cycles per watering event. Auto
Water activation is via Relay 2 by
default.
Daily Charging Schedule
Daily lockout periods can be set by
dragging three bars horizontally.
Green and red sections indicate go
and no-go periods respectively.
Start Time Delay
Set a delay in hours:minutes to
delay charging after the charger
switch is set to Start. Charger
displays a count-down timer to
charge.
Real-Time Clock
Read or set the charger’s internal
clock. An internal cell battery
maintains the RTC in the event of a
power outage.