Harge, Rofiles, Charge profiles tab – DC Power Technologies Charger Interface Software Manual User Manual
Page 16

15
© 2014 Enatel Motive Power Ltd. Specifications subject to change without prior notice. Errors
exempt. Pictures may be representative, actual products may differ.
2.11. Charge Profiles Tab
The charge profile used during
charging
is
selected
in
the
Configuration tab, (if using a
battery module, thecharge profile is
selected in the Battery Module
Configuration tab), however the
Charge Profiles tab is used to
adjust the thresholds that define a
profile and to create all new
profiles.
The charger is programmed with
eight
default
charge
profiles
covering the most common battery
chemistries and can store up to 16
additional
customized
charge
profiles.
Each stage of the charge cycle has
thresholds, timeouts and durations
which may be adjusted to suit
specific batteries and charge rates.
A graphical representation of the
profile is provided reflecting the
threshold values.
Profile Type
The Profile Type drop-down list allows the basic structure of the profile to be selected.
Descriptions of available profile types are listed below.
“Bulk”
“Finishing”
Profile Type
Stage 1
Stage 2
Stage 3
Description
Unused
A profile configured as Unused allows that profile to be rendered
non-functional and is ignored by the charger.
IUIa
Constant
Current
Constant
Voltage
Constant
Current
Standard three stage charge
profile for flooded cells.
Ia
Constant Current
Useful for commissioning or
de-sulphating batteries.
Normal charger min/max
voltage operation parameters
apply.
IUUa
Constant
Current
Constant
Voltage
Constant
Voltage
Useful for infrequent charging
of AGM traction batteries.
IUa
Constant
Current
Constant Voltage
Charging reserve batteries or
using as a power supply.