4.3. Dual Profile

A battery module may be configured to
perform a primary profile charge such
as a high rate opportunity charge, and
follow with a secondary profile charge
after some elapsed time or cycle count.

Alternatively, the battery may

be connected to a second
charger configured just to
charge a single profile - APC
Enabled (Single Profile), in
which case the secondary profile
is used.

Configure a Battery Module for Dual Profile Operation

1. Ensure the battery module is

configured for the battery
ratings as per the Single
Profile instructions above.

2. Select Dual Profile in the

Battery Ratings section.

3. A new section will appear

below

called

Secondary

Profile.

4. In the Primary Profile and

Secondary Profile sections,
enter the required Start
Current and Charge Profile
for each Profile.

5. Select Primary Profile in the

Profile Parameters section,
and select the desired Profile
Type.

6. Ensure the stage threshold

values are appropriate for
the battery and charge
profile type. Select the Auto
EQ/Refresh Options
select
box and choose the required
Dual Profile behaviour:

Bulk Charge Only, Full

Charge

on

Equalise

occurs according to the
Auto Equalise Settings
on

the

charger

(Configuration tab).

Bulk Charge Only, Full

Charge

after

Delay

occurs according the delay
specified in the Auto
EQ/Refresh

After

parameter.

Secondary Profile after

Delay

allows

the

secondary profile to begin
after the delay specified in
the

primary

profile.