Charger configuration, Edicated, Rofile – DC Power Technologies Charger Interface Software Manual User Manual
Page 25: Onfiguration, Utomatic, Dedicated profile configuration, Automatic profile configuration

24
© 2014 Enatel Motive Power Ltd. Specifications subject to change without prior notice. Errors
exempt. Pictures may be representative, actual products may differ.
3. Charger Configuration
The FSx series charger can be operated in a number of different ways, depending on
the configuration of the charger and battery modules.
Dedicated Profile Configuration
This is the standard single battery-type
configuration (voltage, capacity and
chemistry) and default configuration
for the charger. The charger is
manually configured for use with a
single battery configuration and any
battery may be charged provided the
rating matches that of the charger
configuration.
Alternate battery types cannot be
charged without reconfiguring the
charger appropriately.
Automatic Profile Configuration
Any battery module-fitted battery
within the voltage and current
capabilities of the charger can be
connected and charged appropriately.
The battery module provides the
necessary profile information to the
charger once the battery is connected.
3.1. Dedicated Profile Configuration
Configure a charger for use with
a single battery type.
1. Select
the
Charger
Configuration tab.
2. Select the correct battery
type, voltage and capacity
from the drop-down template
menu.
If no battery types are
available, click Import CSV to
populate
the
drop-down
menu from a CSV file.
3. Select the charger size and
AC supply type from the two
adjacent drop-down menus,
click
Use
Values.
The
battery charging parameters
will populate in the Charger
Configuration section.
4. Ensure
the
values
are
appropriate for the charging
configuration and write the
new configuration to the
charger by clicking Write
Configuration.
5. Use
the
Verify
Configuration
option
to
force check the installed
hardware for suitability for
the configuration.
6. The charger front panel will
display
the
new
rating
details.
7. To print a rating label, click
Read Configuration and
then Print Label.
3.2. Automatic Profile Configuration
Configure
a
charger
for
Automatic Profile Configuration
(APC). A battery fitted with a
battery module is required to
utilise
an
APC
configured
charger.
1. From the Configuration tab,
select APC Enabled (Single
Profile) or from the drop-
down menu.
2. For dual profile charging
select APC Enabled (Dual
Profile Capable).
3. Select the charger size and
AC supply type from the two
adjacent drop-down menus,
click
Use
Values.
The
battery charging parameters
will populate in the Charger
Configuration section.
4. Check that the values are
appropriate for the charging
configuration and write the
new configuration to the
charger by clicking Write
Configuration.
5. The charger front panel will
display APC Enabled.
6. Connecting a battery fitted
with a battery module will
automatically configure the