4.5. Backup and Duplicate a Module

Using the appropriate buttons in the Battery Module Configuration tab, a module
configuration may be saved to file and loaded back from file. This process may be used to
easily duplicate configurations across multiple modules. Configuration Access is required to
save to and configure from file.

Save Battery Module Configuration To File

1. Connect the battery to the

charger and ensure the
software is communicating
with the battery module.
Select the Battery Module
Configuration
tab.

2. Confirm

the

module

is

communicating by clicking

Read

Configuration

to

display the module’s current
parameters.

3. Click Save Battery Module

Configuration to File

4. The software will prompt for

a save location and file
name.

Configure Battery Module From File

1. Connect the battery to the

charger and ensure the
software is communicating
with the battery module.
Select the Battery Module
Configuration
tab.

2. Click

Configure

Battery

Module From File and

select the desired MPC file
containing battery module
configuration.

3. Once the configuration is

complete,

click

Read

Configuration to confirm
the module has the new
configuration.

4.6. Electrolyte Level Monitoring

1. Select

the

Module

Configuration tab and click
Read Configuration.

2. Check

the

Electrolyte

Sensor Fitted option and
click Write to program the
settings into the charger.

When

the

module

determines the electrolyte
level is low, an Electrolyte
Level Low Alarm will be
raised

and

an

auto

watering-enabled charger
will receive an instruction
to initiate a watering cycle,
if connected to the battery.