Ackup and, Uplicate a, Odule – DC Power Technologies Charger Interface Software Manual User Manual
Page 30: Lectrolyte, Evel, Onitoring, Backup and duplicate a module, Electrolyte level monitoring

29
© 2014 Enatel Motive Power Ltd. Specifications subject to change without prior notice. Errors
exempt. Pictures may be representative, actual products may differ.
4.5. Backup and Duplicate a Module
Using the appropriate buttons in the Battery Module Configuration tab, a module
configuration may be saved to file and loaded back from file. This process may be used to
easily duplicate configurations across multiple modules. Configuration Access is required to
save to and configure from file.
Save Battery Module Configuration To File
1. Connect the battery to the
charger and ensure the
software is communicating
with the battery module.
Select the Battery Module
Configuration tab.
2. Confirm
the
module
is
communicating by clicking
Read
Configuration
to
display the module’s current
parameters.
3. Click Save Battery Module
Configuration to File
4. The software will prompt for
a save location and file
name.
Configure Battery Module From File
1. Connect the battery to the
charger and ensure the
software is communicating
with the battery module.
Select the Battery Module
Configuration tab.
2. Click
Configure
Battery
Module From File and
select the desired MPC file
containing battery module
configuration.
3. Once the configuration is
complete,
click
Read
Configuration to confirm
the module has the new
configuration.
4.6. Electrolyte Level Monitoring
1. Select
the
Module
Configuration tab and click
Read Configuration.
2. Check
the
Electrolyte
Sensor Fitted option and
click Write to program the
settings into the charger.
When
the
module
determines the electrolyte
level is low, an Electrolyte
Level Low Alarm will be
raised
and
an
auto
watering-enabled charger
will receive an instruction
to initiate a watering cycle,
if connected to the battery.