beautypg.com

Print label – DC Power Technologies Charger Interface Software Manual User Manual

Page 11

background image

10

© 2014 Enatel Motive Power Ltd. Specifications subject to change without prior notice. Errors

exempt. Pictures may be representative, actual products may differ.

Nominal Voltage

As defined by the battery, typically
24V/36V/48V

Start Current

Defines the maximum current
delivered in the first stage of the
charge, as recommended by the
battery manufacturer.

Battery Rating

Capacity of the battery, measured
by discharge rate x discharge time.
Typical

motive

batteries

are

measured at a 5 hour (“C5”) rate,
e.g. a 500Ah battery can be
discharged for 5 hours at 100A.

Typical Battery Temperature

An indicative value of the battery
temperature

that

assists

in

managing parameters during a
charge.

Typical Cable Temperature

An indicative value of the battery
cable temperature that assists in
managing parameters during a
charge.

Charge Profile

Profile as selected according to the
battery type and requirements.
Profiles are defined in the Charge
Profiles tab.

Charger Cable Length

Length of cable from charger to
battery. An indicative value used to

manage

parameters

while

charging.

Cable Cross-Sectional Area

Gauge of cable from charger to
battery. An indicative value used to
manage

parameters

while

charging.

Verify Configuration

When

enabled

during

Write

Configuration the charger checks
that the installed modules can
meet the requirements of the
chosen configuration.

Should the required configuration
exceed the capacity of the installed
modules, install further modules or
a larger capacity charger is
required.

Print Label

2.4.5.

Label printing options include
printer selection, label size and
orientation selections. A layout
preview allows selection or removal
of fields from the resulting printout.
A grey field indicates a field that
will not be printed.