TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–32

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

Retrieve Number
of unread
Stored Alarms

E

N/A

2 bytes

Query only.
Returns the number of stored events, which remain
unread in the alarm log. A maximum of 255 events
may be stored in the alarm log. Numbers over 99 will
be reported as 99.

Example reply: <1/TNA? ’cr’
>0001/TNA=14’cr’’lf’

TNA= TNA?

TNA=xx

(See description
for details of
arguments)

Terminal Status
Change

N/A

1 byte

Query only.
Indicates if there has been a change in the
configuration since the last time the command was
given. A value of 0 indicates no status change, and a
value of 1 indicates there has been a status change.
A status change is defined as any time a parameter is
changed. Such as when command is successfully
executed that changes a value. A status change also
results when there is a redundant switchover, or a
fault condition. A query does not set the status
change flag. The status change flag is cleared after
being read.
Example: <1/TSC?’cr’
>0001/TSC=0’cr’’lf’

TSC= TSC?

TSC=x

(See description
for details of
arguments)