TRP500-4450 C-band Outdoor Amplifier
Revision 1
Ethernet Management
MN-TRP500
4–16
Once the desired configuration settings have been made in this section, the user should then click
[Change Configuration] to save these changes. If it is desired to revert back to the previously
assigned Amplifier settings, the user should instead click [Reset].
Low Forward Power Threshold (dBm)
Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. If the
forward power drops below the specified value, the alarm/fault will be indicated if the forward
power monitor is set to Alarm or Fault instead of the factory default of Mask. Setting this
parameter to the default value of 00.00 effectively disables the threshold.
•
Alarm Masking: Using the drop-down menu, select the alarm mask as Fault, Alarm, or
Masked.
Once the desired configuration setting has been made in this section, the user should then click
[Change] to save this change.
To update the page appearance to the current operating configuration, click [Refresh].
High Reverse Power Threshold (dBm)
Use this field to set the threshold value, in dBm, for the high reverse power alarm/fault. If the
reverse power rises to the specified value, the alarm/fault will be indicated if the reverse power
monitor is set to Alarm or Fault instead of the factory default of Mask. Setting this parameter to
the default value of 00.00 effectively disables the threshold.
•
Alarm Masking: Using the drop-down menu, select the alarm mask as Fault, Alarm, or
Masked.
Once the desired configuration setting has been made in this section, the user should then click
[Change] to save this change.
To update the page appearance to the current operating configuration, click [Refresh].
Serial
• Remote Address: Enter a valid physical remote address between 0001 to 9999.
• Baud Rate: Using the drop-down menu, select the operating baud rate as 2400, 4800,
9600, 19200, or 38400 baud
Once the desired configuration settings have been made in this section, the user should then click
[Change Serial Configuration] to save these changes.