beautypg.com

Comtech EF Data TRP500 User Manual

Page 94

background image

TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–28

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

Retrieve Next 5
unread stored
Events

N/A 75

bytes

Query only.
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}
Sub-body{CR}Sub-body,
where Sub-body= ABCCddmmyyhhmmss:
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=RF
3=Log
CC is Fault Code numbers, as in RAS? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
RAS fault codes map as follows:
1) P24V1
2) P24V2
3) LNBVT

4) P13VT

5) A10V1

6) A10V2

7) 10VPS
8) P5V8T

9) P2V5T
10) P1V2T

11) N5V8T
12) P7V8T

13) FANR1
14) FANR2
15) ATEMP
16) SHTDN
17) IICST
18) FWPWR
19) CHKSM
20) FPGAD
21) BUCLD
22) REFLD
23) LNBCS
24) SWITC
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
A Global Config Change is defined as any time a command is
successfully executed. A query does not set the status change
flag. The status change flag is cleared after being read. No other
events toggle a status change.

RNE= RNE?

RNE={CR}ABCC
ddmmyyhhmmss{
CR}ABCCddmmy
yhhmmss{CR}AB
CCddmmyyhhmm
ss{CR}ABCCddm
myyhhmmss{CR}
ABCCddmmyyhh
m
mss

(See description
for details of
arguments)