beautypg.com

3 web server interface access – Comtech EF Data TRP500 User Manual

Page 43

background image

TRP500-4450 C-band Outdoor Amplifier

Revision 1

Ethernet Management

MN-TRP500

4–7

3. Enter the Telnet

username and password
(the default for both
parameters is comtech):








4. Set the remote access

parameter to accept
Ethernet remote control
using the LRS
command.

LRS=3, the default
remote command,
provides Serial +
Ethernet control
, while
remote command
LRS=2 provides
Ethernet control only.

Note: Each unit on the network must have its own unique IP address before it is connected to an
existing network. The IP address may need to be changed to something other than the factory
default setting by using the command IPA=xxx.xxx.xxx.xxx.yy, where: xxx.xxx.xxx.xxx is a
valid IP address on the network where the unit will be installed, and yy is the range (typically,
yy = 24).

Changing the IPA value will require the user to cycle power on the unit, and then start a new
Telnet session using the new IP address.

See Appendix B. REMOTE CONTROL for more information on the LRS and IPA commands.

4.5.3 Web Server Interface Access

1. From the PC, type http://192.168.1.4 (the default IP address for the TRP500) into the Address

area of the Web browser: