beautypg.com

Comtech EF Data TRP500 User Manual

Page 92

background image

TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–26

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

RF Power FET
Current status

N/A variable

length

depending on the

number of FETs

installed in the RF

amplifier

Query only.
Used to display all the FET currents.
Example: <1/RFS? ’cr’
>0001/RFS=’cr’
Q01=.xxx’cr’
Q02=.xxx’cr’
Q03=xx.x’cr’
Q04=xx.x’cr’
Q05=xx.x’cr’
Q06=xx.x’cr’
Q07=xx.x’cr’
Q08=xx.x’cr’
Q09=xx.x’cr’
Q10=xx.x’cr’
Q11=xx.x’cr’
Q12=xx.x’cr’
Q13=xx.x’cr’
Q14=xx.x’cr’
Q15=xx.x’cr’
Q16=xx.x’cr’’lf’
Note: If the value is one amp or greater the format is
xx.x, and if the value is less than one amp then the
format is .xxx

RFS= RFS?

RFS=x….x

(See description
of arguments)