3 snmp traps – Comtech EF Data TRP500 User Manual

Page 39

background image

TRP500-4450 C-band Outdoor Amplifier

Revision 1

Ethernet Management

MN-TRP500

4–3

4.3.3 SNMP Traps

The TRP500 has the ability to send out SNMP traps when certain events occur in the unit. The
TRP500 sends out traps when a fault occurs in the unit. A trap is sent both when a fault occurs
and is cleared.

The TRP500 supports both SNMPv1 traps and SNMPv2 notifications. Which style of traps the
TRP500 sends can be configured by the user using the TRP500 SNMPTrapVersion OID.

The following are the MIB2 v1traps / v2 notifications that the TRP500 supports:

MIB2 SNMPv1 trap: Authentication Failure

5

MIB2 SNMPv2 notifications: Authentication Failure

1.3.6.1.6.3.1.1.5.5

The following tables are the Faults v1 traps / v2 notifications supported by the TRP500,
excluding those denoted with **italics **.

Faults SNMPv1 traps:

ODUPowerSupply24V1StatusV1 62474801

ODUPowerSupply24V2StatusV1 62474802

ODUPowerSupplyLNBStatusV1 62474803

ODUPowerSupply13VStatusV1 62474804

ODUPowerSupply10VStatusV1 62474805

ODURFPowerSupply10V1StatusV1 62474806

ODURFPowerSupply10V2StatusV1 62474807

ODUPowerSupply7V8TStatusV1 62474808

ODUPowerSupply5V8TStatusV1 62474809

ODUPowerSupply2V5TStatusV1 62474810

ODUPowerSupply1V2TStatusV1 62474811

ODUPowerSupplyNeg5V8TStatusV1 62474812

ODUFan1StatusV1 62474813

ODUFan2StatusV1 62474814

ODUTemperatureStatusV1 62474815

ODUShutdownStatusV1 62474816

ODUI2CStatusV1 62474817

ODUForwardPowerStatusV1 62474818

ODUChecksumStatusV1 62474819

ODUFPGADoneStatusV1 62474820