Comtech EF Data TRP500 User Manual
Page 83
TRP500-4450 C-Band Outdoor Amplifier
REVISION 1
Appendix B
MN-TRP500
B–17
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Initialize Events
Pointer
IEP= None Command
only.
Resets internal pointer to allow RNE? Queries to start
at the beginning of the stored events log.
Example: <1/IEP=’cr’
>0001/IEP=’cr’’lf’
IEP=
IEP?
IEP*
N/A N/A
Firmware Image
IMG=
1 byte
Command or Query.
Current Active software image, where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
Examples:
<1/IMG=1’cr’ (instructs the unit to load firmware from
image #1 at the next reset / power up).
<1/IMG?’cr’ (queries the image number that the
firmware loaded during bootup)
Note: if you send the IMG command, and then query
the IMG value the numbers may not be equal because
the command tells the firmware which image to boot
from at the next bootup, and the query reports the
image that the firmware booted from on the last bootup.
IMG=
IMG?
IMG*
IMG#
IMG?
IMG=x
(See description
of arguments)
IP Address
IPA=
18 bytes
Command or Query.
Used to set the IP address and network prefix for the
10/100 BaseT Ethernet management port, in the
format:
xxx.xxx.xxx.xxx.yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (8-30)
Example: <1/IPG=192.168.001.004.24’cr’
>0001/IPG=’cr’’lf’
Note: Changing the IP address through the Telnet
interface requires the user to power cycle the unit,
and then restart a new Telnet session with the new IP
address. The IP address that you type into the Telnet
client software does not include the range parameter
so it would be: 192.168.1.4
Default Value: 192.168.001.004.24
IPA=
IPA?
IPA*
IPA#
IPA? IPA=
xx.xxx.xxx.xxx.yy
(See description