beautypg.com

Comtech EF Data TRP500 User Manual

Page 79

background image

TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–13

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

Concise
Maintenance
Status

N/A 95

bytes

Query only.
Used to Query the Maintenance status of the unit in a
concise format. The response is semicolon delimited.
This is the concise version of the RMS command.
Example: <1/CMS?
>0001/CMS=aaa.a;bbb.b;ccc.c;ddd.d;eee.e;fff.f;
ggg.g;hh.h;iii.i;jjj.j;kkk.k;lll.l;mmm.m;
nnn.n;ooo.o;ppp.p;qqq.q;rrr.r;sss.s;’cr’’lf’
Where:
aaa.a = P24V1
bbb.b = P24V2
ccc.c = P13VT
ddd.d = P10V1
eee.e = P10V2
fff.f = A10V1
ggg.g = A10V2
hhh.h = P7V8T
iii.i = P5V8T
jjj.j = P2V5T
kkk.k = P1V2T
lll.l = N5V8T
mmm.m = FANR1
nnn.n = FANR2
ooo.o = FANR3
ppp.p = FWPWR
qqq.q = RVPWR
rrr.r = ATEMP
sss.s = OTEMP

CMS= CMS?


CMS=x….x

(See description
for details of
arguments)

Clear Statistics
Log

CSL=

1 byte

Command only.
Used to clear the statistics log entries.
Example:
<1/CSL=1’cr’
>0001/CSL=’cr’’lf’

CSL=
CSL?
CSL*

N/A CSL=