2.2.4 COMM 1 Connector J6 (Remote Communications/Discrete Cntrl Port)
The COM1/Discrete Control connector J6 is the primary input for
controlling and monitoring the SSPA. It is a 19-pin circular
connector, type MS3112E14-19S. The pinout specification is
contained in Table 2-2.
Mating connector: ITT KPT06J14-19P or MS3116J14-19P.
Table 2-2. Connector J6 Pinout
Pin
Name
Description
A RS485_+RX
B RS485_-RX
C RS485_+TX
D RS485_-TX
E
RS232_RD
Pin 3 of DB9 female connector
F
Ethernet TX+
Pin 3 of RJ45 female connector
G
RS232_TD
Pin 2 of DB9 female connector
H
Ethernet TX-
Pin 6 of RJ45 female connector
J
TX/RX Switch Drive 1 Pos Not for customer use
K
Gnd
Ground (also Pin 5 of DB-9F connector)
L
SUMFLT In
Open when faulted, else tied to Pin K
M
SUMFLT Out
When faulted, tied to Pin K, else open
N
TX Switch Pos 1 Ind
Online/Offline indication
P
RX Switch Pos 1 Ind
Not for customer use
R
+24V
Not for customer use
S
System Mute Control
System muted if customer ties to Pin K
T
Switch Common
GND reference for Pin N
U
Ethernet RX-
Pin 2 of RJ45 female connector
V
Ethernet RX+
Pin 1 of RJ45 female connector
2.2.5 Output Sample Port Connector, J9
The Output Sample port connector is a Type ‘N’ female connector that
provides a nominal -50 dB sample of the output signal. A calibration
label is provided near the connector that shows the actual coupling
values vs. frequency.