beautypg.com

Comtech EF Data TRP500 User Manual

Page 90

background image

TRP500-4450 C-Band Outdoor Amplifier

REVISION 1

Appendix B

MN-TRP500

B–24

Parameter Type

Command
(Instruction
Code and
Qualifier)

Arguments for
Command or
Response to
Query

Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)

Response to
Command
(Target to Controller)

Query
(Instruction
Code and
Qualifier)

Response to
Query
(Target to
Controller)

Retrieve Alarm
Status

N/A 168

bytes

Query only.
Used to Query the Alarm status of the unit, where:
OK = no fault condition,
FT = faulted,
AL = alarm,
YS = Yes,
NO = No,
MS = masked.
Example:
<1/RAS?’cr’
>0001/RAS=’cr’
P24V1=OK’cr’ +24V power supply
P24V2=OK’cr’ +24V switch pwr supply
P13VT=OK’cr’ +13.5V power supply
P10V1=OK’cr’ +10V power supply 1
P10V1=OK’cr’ +10V power supply 2
A10V2=OK’cr’ +10V1 RF supply
A10V2=OK’cr’ +10V2 RF supply
P7V8T=OK’cr’ +7.8V power supply
P5V8T=OK’cr’ +5.8V power supply
P2V5T=OK’cr’ +2.5V power supply
P1V2T=OK’cr’ +1.2V power supply
N5V8T=OK’cr’ -5.8V power supply
FANR1=OK’cr’ Fan 1 speed
FANR2=OK’cr’ Fan 2 speed
FANR3=OK’cr’ Fan 3 speed
ATEMP=OK’cr’ Amplifier temperature
SHTDN=OK’cr’ Over-temp shutdown
IICST=OK’cr’ I2C bus status

FWPWR=OK’cr’ Forward power in dBm
RVPWR=OK’cr’ Reverse power in dBm
CHKSM=OK’cr’ Flash checksum
FPGAD=OK’cr’ FPGA done status
SWITC=OK’cr’ Waveguide switch position status
RDLNK=OK’cr’ Redundant link status
TRMST=YS’cr’’lf’ Terminal Status

RAS= RAS?


RAS=x….x

(See description
for details of
arguments)

Reboot

RBT=

1 byte

Soft Reboot
1 = Reboot System

RBT =
RBT?
RBT*

N/A RBT=x


(See description
for details of
arguments)