Comtech EF Data TRP500 User Manual
Page 86
TRP500-4450 C-Band Outdoor Amplifier
REVISION 1
Appendix B
MN-TRP500
B–20
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Local/Remote
State
LRS=
1 byte
Command or Query.
Set Local or Remote for Indoor SSPA. Always in
remote mode for Outdoor SSPA
0 = Local, 1=Serial, 2=Ethernet, 3=Serial+Ethernet
Example: <1/LRS=3’cr’
>0001/LRS=’cr’’lf’
Note: The user will always have query access in any
mode. Also, the LRS command is available in all
modes as a means of acquiring control. The intent of
this command is to limit changes from being made on
multiple interfaces at the same time. Units without a
front panel will treat an entry of 0 as reserved, and will
refuse the command by returning a mode error. The
web page GUI will refuse connections unless LRS is
set to enable Ethernet remote control.
Default Value: 3 (Serial+Ethernet)
LRS=
LRS?
LRS? LRS=x
(Same format as
command
arguments)
Unit MAC
Address
N/A
17 bytes
Query only.
MAC address of the unit, reported in hexadecimal.
Example: <1/MAC?’cr’
>0001/MAC=00-06-B0-00-D2-A7’cr’’lf’
MAC=
N/A MAC=xx-xx-xx-
xx-xx-xx
(See description
for details of
arguments)