Comtech EF Data TRP500 User Manual
Page 97
TRP500-4450 C-Band Outdoor Amplifier
REVISION 1
Appendix B
MN-TRP500
B–31
Parameter Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric
codes between 48 and 57)
Response to
Command
(Target to Controller)
Query
(Instruction
Code and
Qualifier)
Response to
Query
(Target to
Controller)
Serial Number
N/A
9 bytes
Query only.
Used to Query the unit’s nine-digit serial number in
the form of SNO=xxxxxxxxx, where:
xxxxxxxxx is the unit’s nine-digit serial number.
Note: this command is functionally identical to RSN.
Example: <1/SNO?’cr’
>0001/SNO=072282040’cr’’lf’
SNO= SNO?
SNO=xxxxxxxxx
(See description
for details of
arguments)
Remote Address
SPA=
4 bytes
Command or Query.
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: <1/SPA=0412’cr’
>0001/SPA=’cr’’lf’
Default Value: 0001
SPA=
SPA?
SPA*
SPA?
SPA=xxxx
(Same format as
command
arguments)
Set Statistics
Interval
SSI=
2 bytes
Command or Query.
Sets the interval at which statistics are logged.
Minimum resolution is 1 minute, maximum is 99
minutes.
Example: <1/SSI=90’cr’
>0001/SSI=’cr’’lf’
Default Value: 90
SSI=
SSI?
SSI? SSI=xx
(Same format as
command
arguments)
Set RTC Time
TIM=
6 bytes
Command or Query.
A command in the form hhmmss, indicating the time
from midnight, where hh = hours, between 00 and 23;
mm = minutes, between 00 and 59, and ss =
seconds, between 00 and 59
Example (time = 23 hours, 12 minutes and 59
seconds since midnight):
<1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
TIM =
TIM?
TIM *
TIM?
TIM=xxxxxx
(Same format as
command
arguments)
Temperature
N/A
5 bytes
Query only.
Returns the temperatures of the Heatsink in the form
of a sign byte followed by 4 bytes for the temperature.
Example: TMP=+26.0
TMP= TMP?
TMP=sxxx
(See description
for details of
arguments)